Envie-nos um e-mail:[email protected]

Ligue para nós:+86-13709018859

Todas as Categorias

Inversor de armazenamento de energia

Página Inicial >  Produtos >  Inversor de armazenamento de energia

inversor Híbrido de 12 kW, Inversor Híbrido de Fase Dividida de 8 kW, Inversor de Fase Dividida 120/240 V, Inversor de Fase Dividida de 10 kW para Sistema Solar Isolado da Rede

Descrição do produto
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System factory
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System factory
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System details
ESPECIFICAÇÃO
Modelo
GES48120M220-500P
Modo Paralelo
Número paralelo permitido
NÃO/1~6
Modo AC
Voltagem de Entrada Nominal
120(L1/N,L2/N)/240Vac(L1/L2)
Faixa de Tensão de Fase de Entrada
(85Vac~140Vac)±2%
Freqüência
50Hz/60Hz (Detecção Automática)
Faixa de frequência
47±0,3Hz~55±0,3Hz(50Hz);
57±0,3Hz~65±0,3Hz(60Hz);
Eficiência
>95%
Tempo de conversão (bypass e inversor)
10ms(típico)
Proteção contra polaridade reversa da tomada AC
Sim
Corrente máxima de sobrecarga de fase do bypass
2 polos, 60A/60A(L1/L2)
Modo inversor
Forma de onda da tensão de saída
Onda senoidal pura
Potência de saída nominal (VA)
Fase dividida: 12000
Monofásico: 7200
(limitado pelos terminais de fiação)
Potência de saída nominal (w)
Fase dividida: 12000
Monofásico: 7200
(limitado pelos terminais de fiação)
Fator de potência
1
Tensão de Saída Nominal (VAC)
120Vac(L1/N,L2/N)/240Vac(L1/L2)
Erro de tensão de saída
±5%
Faixa de Frequência de Saída (Hz)
50Hz±0,3Hz/60Hz±0,3Hz
Eficiência máxima
>91%
Proteção contra sobrecarga
(105%(110%Carga>125%±5%: relatar erro e desligar a saída após 5 segundos;
Potência de pico
Fase dividida: 18000VA
Fase única: 18000VA
Capacidade de motor carregado
6CV
Proteção contra curto-circuito na saída Pode proteger, após curto-circuito contínuo por 1 segundo
Especificação do disjuntor do circuito de by-pass
2 polos, 63A/63A(L1/L2)
Tensão nominal de entrada da bateria 51,2V (Tensão mínima de partida 44V)
Faixa de tensão da bateria
40,0Vcc~58,6Vcc±0,6Vcc(Tensão de subtensão alarme/desligamento/sobretensão
alarme/recuperação de sobretensão. Configurável na tela LCD)
Modo de economia de energia - consumo próprio Carga ≤25W entra em modo de economia de energia
Tipo de bateria
Bateria de chumbo ou de lítio
Corrente máxima de carga (pode ser definida)
160A
Erro da corrente de carga
±5Adc
Faixa de tensão de carga
40-58,6Vdc
Proteção contra curto-circuito
Disjuntor e fusível queimado
Especificações de fase do disjuntor
2 polos, 60A/60A(L1/L2)
Descrição dos Produtos
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System factory
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System factory
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System supplier
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System details
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System manufacture
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System factory
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System details
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System factory
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System supplier
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System details
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System factory
Recomendar Produtos
Perfil da empresa
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System manufacture
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System details
Exposição
12kw Hybrid Inverter 8kw Split Phase Hybrid Inverter Split Phase 120 240 Inverter Split-phase 10kw for Off-Grid Solar System details
Perguntas frequentes
P1: Este inversor possui certificação UL?
Sim. Este inversor de 12 kW possui certificação UL para os mercados dos Estados Unidos e do Canadá.
P2: Vocês têm estoque nos EUA?
Sim. Temos estoque disponível em nossos depósitos nos Estados Unidos para entrega rápida.
P3: Qual é a saída fornecida por ele?
fase dividida de 120 V / 240 V, 60 Hz, adequado para sistemas elétricos da América do Norte.
P4: Ele pode operar ar-condicionados, bombas e motores?
Sim. Ele suporta alta potência de pico para cargas motorizadas, sendo ideal para ar-condicionados, geladeiras, bombas d’água, compressores e ferramentas elétricas.
P5: Quais baterias são compatíveis?
recomendam-se baterias de lítio LiFePO₄ de 48 V / 51,2 V.
P6: Ele suporta conexão solar e à rede elétrica?
Sim. Suporta energia solar, bateria e rede elétrica (modelos híbridos), para aplicações off-grid, de reserva ou comerciais.
P7: É possível conectar várias unidades em paralelo?
Sim. Até 6 unidades podem ser conectadas em paralelo, alcançando uma potência combinada máxima de 72 kW.
P8: Vocês oferecem serviços de OEM e ODM?
Sim. Serviços de OEM e ODM estão disponíveis.
×

ENTRE EM CONTATO