MODEL AC Input/Output Data |
HESP48140UH3 |
HESP48160UH3 |
HESP48180UH3 |
||||||||
Rated AC Input/Output Active Power |
14000W |
16000W |
18000W |
||||||||
Max. AC Input/Output Apparent Power |
15400VA |
17600VA |
19800VA |
||||||||
Rated AC Input/Output Current |
44.5A/38.8A |
50A/44.5A |
55.5A/50A |
||||||||
Max. AC Input/Output Current |
44.5A/38.8A |
50A/44.5A |
55.5A/50A |
||||||||
Peak Power (off-grid) |
28000VA |
32000VA |
36000VA |
||||||||
Power Factor Adjustment Range |
0.8 leading to 0.8 lagging |
||||||||||
Rated Input/Output Voltage/Range |
120/208V 0.85Un-1.1Un |
||||||||||
Rated Input/Output Grid Frequency/Range |
60Hz/40Hz-70Hz |
||||||||||
Grid Connection Form |
3L+N+PE |
||||||||||
THD |
<3% (of nominal power) |
||||||||||
Battery Input Data |
|||||||||||
Battery Type |
Lead-Acid Batteries / Lithium Batteries / User-defined |
||||||||||
Number of Battery Input |
2 |
||||||||||
Battery Voltage Range |
40V-60V |
||||||||||
Max. Grid/Generator Charging Current |
300A |
330A |
350A |
||||||||
Max. Hybrid Charging Current |
300A |
330A |
350A |
||||||||
Max. Discharging Current |
300A |
330A |
350A |
||||||||
Charging Strategy for Li-ionBattery |
Self-adaption to BMS |
||||||||||
PV Input Data |
|||||||||||
No. Of MPPT Trackers |
3 |
||||||||||
No. of Strings MPPT Tracker |
2+2+2 |
||||||||||
Max. PV Access Power |
28000W |
32000W |
36000W |
||||||||
Max. PV Input Power |
22400W |
25600W |
28800W |
||||||||
Rated PV Input Voltage |
450V |
||||||||||
Max. PV Input Voltage |
600V |
||||||||||
Start-up Voltage |
120V |
||||||||||
Max. PV Input Current |
40A/40A/40A |
||||||||||
Max. Input Short-Circuit Current |
50A/50A/50A |
||||||||||
MPPT Voltage Range |
120V-500V |
||||||||||
Grid/Generator Input |
|||||||||||
Input Voltage Range |
Phase voltage: 90V-140V, line voltage: 156V-243V |
||||||||||
Input Frequency Range |
40Hz-70Hz |
||||||||||
Max. Bypass Overload Current (Grid) |
200A |