All Categories
240v solar inverter on off grid 120vac 240vac split phase hybrid solar inverter-1

Energy Storage Inverter

Home >  Products >  Energy Storage Inverter

US Certification 48V 5KW 8KW 10KW 120v/240v Solar Inverter on Off Grid 120VAC 240VAC Split Phase Hybrid Solar Inverter

Product Description
240v solar inverter on off grid 120vac 240vac split phase hybrid solar inverter-2
240v solar inverter on off grid 120vac 240vac split phase hybrid solar inverter-3
240v solar inverter on off grid 120vac 240vac split phase hybrid solar inverter-4
Specification
Model
GES48120M220-500P
Parallelmode
Permitted parallel number
NO/1~6
AC mode
Rated input voltage
120(L1/N,L2/N)/240Vac(L1/L2)
Input phase voltage range
(85Vac~140Vac)±2%
Frequency
50Hz/60Hz(Automatic detection)
Frequency Range
47±0.3Hz~55±0.3Hz(50Hz);
57±0.3Hz~65±0.3Hz(60Hz);
Efficiency
>95%
Conversion time(bypass and inverter)
10ms(typical)
AC reverse protection
Yes
Maximum bypass phase overload curent
2 pole,60A/60A(L1/L2)
Inverter mode
Output voltage waveform
Pure sine wave
Rated output power (VA)
Split phase:12000
Single phase:7200
(limited by the wiring terminals)
Rated output power (W)
Split phase:12000
Single phase:7200
(limited by the wiring terminals)
Power factor
1
Rated output voltage (Vac)
120Vac(L1/N,L2/N)/240Vac(L1/L2)
Output voltage error
±5%
Output frequency range(Hz)
50Hz±0.3Hz/60Hz±0.3Hz
Maximum Efficiency
>91%
Overload protection
(105%(110%Load>125%±5%:report error'and turn off the output after 5 seconds;
Peak power
Split phase:18000VA
Single phase:18000VA
Loaded motor capability
6HP
Output short circuit protection Can protect,after continuous short circuit for 1 second
Bypass circuit breaker phasespecification
2 pole,63A/63A(L1/L2)
Rated battery input voltage 51.2V(Minimum starting voltage 44V)
Battery voltage range
40.0Vdc~58.6Vdc±0.6Vdc(Undervoltage alarm/shutdown voltage/overvoltage
alarm/overvoltage recovery.settáble on LCD screen)
Power saving mode self-consumption Load≤25W enter power-saving mode
Battery type 
Lead acid or lithium battery
Maximum charge current(can be set)
160A
Charge current error
±5Adc
Charge voltage range
40-58.6Vdc
Short circuit protection
Circuit breaker and blown fuse
Circuit breaker phase specifications
2 pole,60A/60A(L1/L2)
240v solar inverter on off grid 120vac 240vac split phase hybrid solar inverter-5
240v solar inverter on off grid 120vac 240vac split phase hybrid solar inverter-6
240v solar inverter on off grid 120vac 240vac split phase hybrid solar inverter-7
240v solar inverter on off grid 120vac 240vac split phase hybrid solar inverter-8
240v solar inverter on off grid 120vac 240vac split phase hybrid solar inverter-9
240v solar inverter on off grid 120vac 240vac split phase hybrid solar inverter-10
240v solar inverter on off grid 120vac 240vac split phase hybrid solar inverter-11
240v solar inverter on off grid 120vac 240vac split phase hybrid solar inverter-12
Recommend Products
Company Profile
240v solar inverter on off grid 120vac 240vac split phase hybrid solar inverter-13
240v solar inverter on off grid 120vac 240vac split phase hybrid solar inverter-14
240v solar inverter on off grid 120vac 240vac split phase hybrid solar inverter-15
×

Get in touch