Model |
R12KLNA |
R16KLNA |
||
PV input data |
||||
Max. PV input power (kW) |
18 |
24 |
||
Max. PV input voltage (V) |
500 |
|||
Min. PV input voltage (V) |
120 |
|||
Start-up voltage (V) |
120 |
|||
MPPT voltage range (without battery)(V) |
120~500 |
|||
MPPT voltage range@full-load (V) |
150~430 |
|||
Rated PV input voltage (V) |
310 |
|||
No. of MPPT trackers |
4 |
|||
No. of strings per MPPT tracker |
1/1/1/1 |
|||
Max. input current per MPPT (A) |
16/16/16/16 |
20/20/20/120 |
||
Max. short-circuit current per MPPT (A) |
22/22/22/22 |
25/25/25/25 |
||
Battery input data |
||||
Battery type |
Lithium-ion / Lead-acid |
|||
Max. charge / discharge power (kW) |
12 |
13 |
||
Battery voltage range (V) |
40~58 |
|||
Rated battery voltage (V) |
48 |
|||
Max. charging / discharging current (A) |
250/260 |
260/280 |
||
Rated charge / discharge current (A |
250/260 |
260/280 |
||
Battery charging strategy |
Self-adaption to BMS |
|||
BMS communication |
CAN |
|||
AC output data (grid side) |
||||
Rated output power (kW) |
12 |
16 |
||
Max. apparent output power (kVA) |
13.2 |
16 |
||
Rated grid voltage( (V) |
110-127/208-240V split phase, 240V single phase |
|||
Grid voltage range (V) |
240 |
|||
Rated grid frequency (Hz) |
60 |
|||
Grid frequency range(Hz) |
55 to 65 |
|||
Rated output current (A) |
50 |
66.7 |
||
Max. AC output current (A) |
55 |
73.3 |
||
Power factor |
0.8leading~0.8lagging |
|||
Max. grid passthrough current(A) |
200 |
|||
THDi |
<3% |
|||
Grid type |
2L+N+PE |
|||
AC output data (load side) |
||||
Rated output power (kW) |
12 |
13 |
||
Max. apparent output power (kVA) |
13.2 |
|||
Rated output voltage (L-N/L1-L2) (V) |
120/240 |
|||
Rated output frequency (Hz) |
60 |
|||
Rated output current (A) |
50 |
54 |
||
Max. AC output current (A) |
55 |
55 |
||
Peak output power |
110%,30s / 120%,10s / 150%,0.02s |
|||
Back-up switch time (ms) |
<20 |
|||
THDu |
<2% |